詳細(xì)說明
UNDERWRITERS LABORATORIESAPPLIANCE WIRING MATERIALSubj.758Section 1Page 10110Issued:1991-10-17?Revised:2008-05-27Style 10110Insulated Wire.Rating105 deg C, Voltage Not Specified, Horizontal flame.Conductor36 AWG - 6 AWG solid or stranded, silver plated or nickel coated and copper, nickel conductor, silver plated zirconium Insulation copper alloy, silver plated cadmium chrome copper alloy, silver plated cadmium bronze copper alloy, or silver plated copper-clad steel, tinned copper.InsulationPFA36-20 AWG conductor size5.5 mils min average5 mils min at any point19-16 AWG8 avg7 min15-10 AWG13 avg12 min9-6 AWG20 avg18 minStandardAppliance Wiring Material UL 758.MarkingGeneral.UseIn back panel areas of electronic equipment, such as electronic computers and business machines, where not subjected to movement or mechanical damage.
以上是UL10110的詳細(xì)信息,如果您對UL10110的價格、廠家、型號、圖片有什么疑問,請聯(lián)系我們獲取UL10110的最新信息。
?